Clinical Chemistry
Serum - The inner wall of the VACUETTEŽ Serum tubes have a special coating of microscopic silica particles to activate the coagulation process.
Serum gel tubes contain an inert barrier gel that is present in the bottom of the tube. During centrifugation the barrier gel moves upward to the
serum - clot interface, where it forms a stable barrier separating the serum from fibrin and cells. VACUETTEŽ Serum Tubes with Gel improve the
serum yield and enable serum to be left in the primary tube. Request more information or samples here.
Back to Greiner Products
^ TOP ^
Plasma-Heparin - The inner wall of the VACUETTEŽ Heparin tubes is coated with spray-dried lithium, ammonium or sodium heparin. The additives are anticoagulants, which block the coagulation cascade and prevent coagulation of the blood sample.
Plasma gel tubes contain an inert barrier gel that is present in the bottom of the tube. During centrifugation the barrier gel moves upward to the plasma - cell interface, where it forms a stable barrier separating the plasma from cells. VACUETTEŽ Plasma Tubes with Gel improve the plasma yield and enable plasma to be left in the primary tube.
Request more information or samples here.
Back to Greiner Products
^ TOP ^
Coagulation
Coagulation - Citrate blood is the most commonly obtained examination sample for coagulation determinations. Sodium citrate functions as anticoagulant by chelating calcium.
The innovative VACUETTEŽ coagulation tubes for coagulation diagnostics with double-wall technology guarantees reliable analysis results, because on the one hand, a long shelf life of the vacuum is guaranteed, whilst on the other hand, a constant mixing ratio for the citrate solution is ensured.
The coagulation tubes contain a buffered sodium citrate solution. The concentration is either 3.2% or 3.8%. The proportion of blood to the sodium citrate anticoagulation volume is 9:1.
The tubes are used for determinations in citrated plasma for coagulation testing. Request more information or samples here.
Back to Greiner Products
^ TOP ^
Hematology
Etad - EDTA binds the calcium ions and therefore blocks the coagulation cascade. Erythrocytes, leucocytes and thrombocytes in an EDTA anticoagulated blood sample are stable for up to 24 hours.
The tube interior of EDTA tubes is spray dried with EDTA. (EDTA - a salt of ethylene diamine tetraacetic acid). EDTA tubes are offered as either K2EDTA or K3EDTA tubes.
Request more information or samples here.
Back to Greiner Products
^ TOP ^
Glucose Determination
Glucose Tubes - Both sodium fluoride and iodoacetate are used in VACUETTEŽ Glucose Tubes as glycolysis inhibitors to preserve glucose when combined with an anticoagulant such as EDTA, potassium oxalate or heparin. The tubes are suitable for determining glucose and lactate.
The VACUETTEŽ glucose tubes contain a stabiliser and an anticoagulant.
- FX Glucose tubes contain sodium fluoride and potassium oxalate
Request more information or samples here.
Back to Greiner Products
^ TOP ^
Molecular Diagnostics
EDTA K2 - EDTA K@ gel tubes are for the examination of EDTA plasma for molecular diagnostics and for viral load determinations
The tube interior is spray dried with K2EDTA. The tubes contain an inert barrier gel that is present in the bottom of the tube. During centrifugation the barrier gel moves upward to the plasma - cell interface, where it forms a stable barrier separating the plasma from cells.
Request more information or samples here.
Back to Greiner Products
^ TOP ^
Blood Sedimentation
The erythrocyte sedimentation rate (ESR) can be used as a non-specific search technique for inflammatory reactions and observing their development. VACUETTEŽ ESR tubes are used for determination of the ESR.
VACUETTEŽ ESR tubes are used for ESR determination. The VACUETTEŽ erythrocyte sedimentation systems (closed and automated) are based on the Westergren method.
The closed VACUETTEŽ ESR System consists of two parts:
1. 9/120mm VACUETTEŽ ESR tube
2. ESR rack with a scale.
The automated VACUETTEŽ ESR System consists of two parts:
3. 9/120mm VACUETTEŽ ESR tube
4. ESR reader.
Request more information or samples here.
Back to Greiner Products
^ TOP ^
Special Diagnostics
Greiner Bio-One offers a broad selection of tubes for blood grouping, for crossmatching, and for determining trace elements.
- CPDA tubes - Blood grouping
- Serum / EDTA crossmatch tubes - Crossmatching
- Serum tube, heparin tube, no additive tube - Determination of trace elements
Request more information or samples here.
Back to Greiner Products
^ TOP ^
Cross Matching - The cross-matching test is a test for compatibility between donor and recipient blood, carried out prior to transfusion.
VACUETTEŽ Crossmatch Tubes are available in two different versions. One tube type contains clotting activator used to make crossmatch tests with serum, while the other type contains K3EDTA and is used to make crossmatch tests with whole blood. The field of application is crossmatching.
Request more information or samples here.
Back to Greiner Products
^ TOP ^
Trace Element Tubes - VACUETTEŽ Trace Element Tubes contain sodium heparin, no additive, or clot activator and are used to test trace elements.
Request more information or samples here.
Back to Greiner Products
^ TOP ^
Blood Grouping Tubes - VACUETTEŽ Blood Grouping Tubes are available with CPDA solution (Citrate Phosphate Dextrose Adenin). The tubes are
suitable for both blood grouping tests and cell preservation.
Request more information or samples here.
Back to Greiner Products
^ TOP ^
No Additive Tubes - These tubes do not contain any additives. They can, for example, be used for CSF determinations.
Request more information or samples here.
Back to Greiner Products
^ TOP ^
Closure Systems
To ensure quick and flexible reactions to the varying requirements in laboratories, Greiner Bio-One can offer VACUETTEŽ Blood Collection Tubes with 13 mm diameter in three different versions.
Whatever the area of application, Greiner Bio-One has the right type of tube. We differentiate between "Ridged" and "Non-Ridged" versions.
All tubes with 16 mm diameter are non-ridged tubes as standard.
Non-Ridged - There are no ridges around the rim of this tube, which means that the cap can be removed with a simple pull movement. This closure system is especially suitable, if caps must be removed from tubes quickly.
Request more information or samples here.
Back to Greiner Products
^ TOP ^
Snap Caps - For recapping VACUETTEŽ tubes which have been opened. Snap Caps are suitable for all 13 mm diameter tubes.
Request more information or samples here.
Back to Greiner Products
^ TOP ^
Safety Tube Holders
Safety Tube Holders - Injuries due to contaminated venipuncture devices are still the primary cause of accidents in hospitals. This is a significant source of danger for many employed in the healthcare sector. The Safety Tube Holders from VACUETTEŽ can provide effective protection against needlestick injuries. Greiner Bio-One has developed two innovative product solutions: the VACUETTEŽ QUICKSHIELD Safety Tube Holder and the new VACUETTEŽ PREMIUM Safety Needle System.
The VACUETTEŽ QUICKSHIELD Safety Tube Holder is especially suitable for application in the daily blood collection routine, due to the user friendly functioning.
The safety cap is activated immediately after blood collection using one hand. With the aid of a solid support, the safety cap closes over the needle. A clearly audible "Click" indicates that the safety mechanism has been activated correctly. The product provides simple user comfort and a high level of safety.
Request more information or samples here.
Back to Greiner Products
^ TOP ^
Safety Blood Collection Set
Safety Blood Collection Set - The Safety Blood Collection Set with integrated needle protection is an important contribution to avoiding needlestick injuries. After use, the safety mechanism is activated inside the patient's vein. To do this, the wings of the set are held in place with the fingers of one hand. With the other hand, the slide is released by pushing together the pieces on the side. The slide is then pulled back. An audible "Click" indicates correct activation.
Request more information or samples here.
Back to Greiner Products
^ TOP ^
Urine Cups
Urine Cups - Improved safety for laboratory and hospital personnel through the use of a closed system; contamination is virtually impossible when decanting into secondary vessel. Also available, without the integrated transfer device.
Request more information or samples here.
Back to Greiner Products
^ TOP ^
Urine Tubes
Urine Tubes - VACUETTEŽ Urine Tubes are used as collection transportation and/or analysis vessel. The VACUETTEŽ Urine tubes are sterile, leak-proof and virtually unbreakable. They are available as round or conical based. Furthermore, they are offered with or without preservative. Tubes with preservatives should be inverted 6-8 times following collection in order to achieve homogenous mixing.
Request more information or samples here.
Back to Greiner Products
^ TOP ^
Urine Transfer Devices
Urine Transfer Devices - Conveniet sample tranfer from the collection Vessel. Only need when not using the Intergrated Tranfer Cup.
Request more information or samples here.
Back to Greiner Products
^ TOP ^
|